- İ -
      Home     ||       About Us     ||      Products     ||        News     ||       case     ||      services    || Contact Us  
 
All Products
- A variety of health Pump
- High Shear Emulsification Machine
- High-tech hose
- A variety of health gasket
- Ice cream production systems
- Grinder
- A variety of health instrument
- Health tube
- Health Stainless Steel Pipe
- A variety of hybrid systems
- A variety of health equipment
- Projects
 
 
 
 
Products / High-tech hose /  MANIFLON/SD-MFA
 
 
Applications
      General-purpose use and distribution of respirable hose can handle high concentrations of solvents and chemicals
      Hose from a new generation of fluoropolymer materials extremely resistant to oxidation, temperature or by the dynamic stress caused by the cracking
      High degree of smooth non-permeable wall is better than any other similar material
      Standards in line with the EM1215
  
  hose structure
      Inner tube
     MFA (perfluoralkoxy polyme polymer), the fluoride treatment, white, smooth, smooth
     High heat resistance and stress rupture resistance, bending resistance and oxidation
     USP approved material by the United States (USP 23 Class VI); the U.S. Federal Drug and Cosmetic approved (FDA Title 21 P.177.1550);
     In accordance with the EU 82/711; 85/572; 90/128; 92/39; 93 / 9; 95 / 3; 96/11 requirements
     Chemical resistance standards: MTG chemistry see chart
   
   structure to strengthen
       Laminated high-strength synthetic cable
       Implanted metal spiral wire
       Built-in copper wire

  surface
       EPDM (ethylene propylene diene monomer), black, smooth, conductive body, wear-resistant, resistant to atmospheric corrosion, cloth-like surface
  
  surface labeling
       Red and white vertical stripes MTG MANIFLON MFA
       Embossed with the vertical line with the EN12115 standard
  
   electrostatic dissipation
       Identify symbols:-M-resistance 10 ohms

  use temperature range
       From -50 to 170 (depending on the transmission capacity)
      
   safety factor:
        75mm diameter 4-fold below the working pressure
        75mm diameter 3 times the work of the following pressure

InternalDiameter
(mm)

WallThickness
(mm)

BendingRadius Static(mm)

WorkingPressure (bar) Vacuum (bar) Theoretical Weight (Kg/m) Lenhth Max (m)
13 6.0 80 16 -0.9 0.60 20
19 6.5 115 16 -0.9 0.80 20
25 6.5 150 16 -0.9 0.95 20
32 6.5 190 16 -0.9 1.20 20
38 6.5 230 16 -0.9 1.50 20
51 7.5 300 16 -0.9 2.20 20
63.5 8 390 16 -0.9 3.00 20
76 8.5 500 16 -0.8 3.70 20
100

OnRequest


All the technical parameters for the test at room temperature 20 benchmark DIMENSIONAL TOLERANCES: Diameter-ISO 1307, Length-ISO 1307, Wall Thickness-DIN 7715-T4-S2
 
       

Copyright © 2009 . nature engineering co.,ltd All Rights Reserved.